TECHNICAL SPECS
Manufactured from hot brass stamped fittings and high quality brass tube complying to BS2871.
Some models manufactured from high grade CR steel tubing and/or containing steel components suitable for closed/indirect circuits only.
In aggressive water areas, or where water softeners are installed, dezincification resistant materials should be specified. Please ask for an individual quotation.
The installation of electrically operated towel rails, when fitted in bathrooms, must comply with current I.E.E. wiring regulations and BS7671. If in doubt consult a qualified electrician. Dual fuel models should be operated in the electric mode with provision for expansion. Manufacturers notes do not override legal obligations.
All rails are pressure tested to 100p.s.i (6.9 bar) air immersed in water.
All models are fitted with 2 x 1º2" BSP F.I connections, excepting LOLA which is unheated. Alternative M.I. or compression fitting is available on request. 3º4" BSP connections available at extra cost on some models.
A manual bleed air vent is fitted to all hot water/dual fuel models.
HINTS & ADVICE
In order to assist your choice of towel rail, the following check points should help to avoid the specification of an unsuitable model.
-
Ensure the space you have is of adequate dimensions and that suitable services can be directed to the location.
-
Check you have sufficient room to accept the projection of the towel rail without impeding access or door opening etc.
-
Ensure the towel rail of your choice is suited to the circuit available. Never install an item containing ferrous (steel) parts on an open circuit. If in doubt, ask!
-
Wherever possible Vogue towel rails are manufactured using dezincification resistant brass. However, it should be understood the term ‘resistant’ does not entirely preclude the possibility of dezincification occurring. If you intend to install the product on an open (DHW) circuit, make reference to your local water authority to ensure dezincification has not previously occurred. Towel rails manufactured from brass tubing should not be installed on an open circuit if a water softener is present. Water analysis to determine the likelihood of dezincification is available at cost. Product compatibility is the responsibility of the installer.
-
Never install a towel rail without providing for suitable isolation.
-
Consider the benefits of an electrical immersion heater for continued operation in the summer months. When utilised, one isolating valve should be turned off to prevent circulation through the system. Appropriate measures should also be taken to ensure the continued venting and filling of the product. On no account should the electric option be operated in tandem with the central heating.
-
All Vogue UK products must be installed in accordance with BS5449, BS7593 and BS7671 to avoid invalidation of the guarantee.
|
|
USER/INSTALLER GUIDE - ELECTRIC UNITS
-
Where applicable installation should be conducted only by a qualified electrician with a sound knowledge of IEE regulations. The heating element in dual fuel units should be installed prior to leak testing of the system. The towel rail must be individually earth bonded.
-
Always ensure the towel rail is protected by a suitably rated fuse (typically 5 amp) or proprietary brand residual circuit breaker.
-
The electrical element within the towel rail is manufactured and inspected to European Standard EN60335-1 (CENELEC) - CE 61/50. It is splash proof only and must never be immersed.
-
The heating element in dual fuel models must never be operated without the towel rail being completely full of water and connected to the central heating system. The system design must guarantee constant filling of the unit. Special care must be taken after any service work requiring ‘drain-off’ of the system.
-
The towel rail must always be installed with the element at the bottom of the unit. Thermal cycling will not occur if the towel rail is installed with the element at the top. Consequential damage to the element will then occur.
-
In dual energy models allowance for thermal expansion must be made by having the return valve partially open. The flow valve must be closed to prevent cycling through the system.
-
Electric only towel rails are designed for continuous operation and are perfectly safe if left switched on permanently. If timed operation is required the time clock utilised should be rated to the wattage of the electric element. On no account should the electric operation of dual fuel models be utilised in conjunction with the central heating operation.
-
All Vogue UK products must be installed in accordance with BS5449, BS7593 and BS7671 to avoid invalidation of the guarantee.
|